This product is suitable for the connection of electronic computer networks and control systems, detection devices and instruments with high anti-interference performance requirements

Production execution standards

Enterprise standard and refer to British Standard BS5308.

Use characteristics

1. Rated voltage UO/U is 300/500V; long-term working temperature of cable conductor: polyvinyl chloride has 70C and 105℃; polyethylene insulation is 70℃; cross-linked polyethylene insulation is 90℃ (insulation cross-linked type Can be divided into silane crosslinking and irradiation crosslinking).

2. The cable can be used for fixed laying under the condition of ambient temperature -40℃~50℃, and the ambient temperature should not be lower than 0℃ during laying.

3. For cables with copper tape shielding structure, the bending radius should not be less than 10 times the outer diameter of the cable when laying; the bending radius should not be less than 12 times the outer diameter of the cable when laying the armored cable; the bending radius when laying other cables should be Not less than 6 times the outer diameter of the cable

Model, structural features

Copper core PVC insulated PVC sheathCopper core PVC insulated PVC sheathCopper core XLPE insulated PVC sheathStructural features
DJVPVDJYPVDJYJPVBraided pair shield (copper wire or tinned copper wire)
DJVP2VDJYP2VDJYJP2VCopper tape pair shield
DJVJP3VDJYPVDJYJP3VAluminum-plastic composite tape pair shield
DJVVPDJYVPDJYJVPBraided overall shield (copper wire or tinned copper wire)
DJVVPDJYVPDJYJVP2Copper tape overall shield
DJVVP2DJYVPsDJYJVP3Aluminum-plastic composite tape overall shield
DJVPVPDJYPVPDJYJPVPWeaving sub and total shielding (copper wire or tinned copper wire)
DJVP2VP2DJYP2VP2DJYJP2VP2Copper tape sub and total shield
DJVP3VP2DJYP3VPDJYJP3VP2Aluminum-plastic composite tape and overall shielding
DJVP2V22DJYP2V22DJYJP2V22Copper tape sub-shielded, armored
DJVP3V22DJYP3V22DJYJP3V22Aluminum-plastic composite tape sub-shielded, armored
DJVVP2-22DJYVP2-22DJYJVP2-22Copper tape overall shield, armored
DJVVP3-22DJYVP3-22DJYJVP3-22Aluminum-plastic composite tape overall shielding, armored
DJVP2VP2-22DJYP2VP2-22DJYJP2VP2-22Copper tape sub and overall shielding, armored
DJVP3VP3-22DJYPaVP3-22DJYJPsVP3-22Aluminum-plastic composite tape, overall shielding, armored
DJVPVRDJYPVRDJYJPVRCompile pair shielding soft structure
DJVP2VRDJYP2VRDJYJP2VRCopper tape pair shielding soft structure
DJVPVPRDJYPVPRDJYJPVPRCompile sub- and total shielding soft structure
DJVP2VP2RDJYP2VP2RDJYJP2VP2RCopper tape sub and overall shielding soft structure

Specification range

Model numberlogarithmNominal section (mm²)
DJVPVDJYPVDJYJPV1~24

0.5,0.75,1.0,1.5,2.5

DJYP2VDJYJP2VDJVP3V
DJYJP3VDJVVPDJYVP
DJVVP2DJYVP2DJYJVP2
DJYVPsDJYJVP2DJVPVP
DJYJPVPDJVP2VP2DJYP2VP2
DJVP3VPsDJYPsVP2DJYJP3VP3
DJVPVRDJYPVRDJYJPVR
DJYP2VRDJYJP2VRDJVPVPR
DJYJPVPRDJVP2VP2RDJYP2VP2R
DJVP2V22DJYP2V22DJYJP2V222~24
DJVP3V22DJYP3V22DJYJP3V22
DJVVP2-22DJYVP2-22DJYJVP2-22
DJVVP3-22DJYVP3-22DJYJVP3-22
DJVP2VP2-22DJYP2VP2-22DJYJP2VP2-22
DJVP3VP3-22DJYPaVP3-22DJYJP3VP3-22

 

Note: Flame-retardant computer cables can also be produced according to needs, just add “ZR” to the model., Such as ZR-DJ Y PVP.

Technical parameter

1. Conductor DC resistance and conductor structure

Nominal cross sectionConductor structure (number of wires / diameter of single wire mm20C DC resistance≤(口/km
ABRA、BR
0.51/0.87/0.316/0.23639
0.751/0.977/0.3724/0.224.526
11/1.137/0.4332/0.218.119.5
1.51/1.387/0.5230/0.2512.113.3
2.51/1.787/0.6849/0.257.417.98

Note: The conductor structure of the computer cable is generally made of Type A or Type R. If users need products with Type B conductor structure, please indicate in the contract when ordering.

2. Insulation resistance: PVC insulation resistance

3. The cable should withstand the power frequency AC voltage test; test voltage: 2000V, test time is 5min, test temperature is ambient temperature

 Nominal cross section of conductor
70℃, 90℃ minimum insulation resistance (MQ·km0.50.7511.52.5
0.0130.0140.0130.010.01
     

Note: The insulation resistance between the cores of polyethylene and XLPE insulated cables and between the core and the shield
When the temperature is 20℃, it should not be less than 500M·km.